The IDCUBE’s new MMR Series Serial Input/
Output (SIO) panels enable system expansion of
MLP series intelligent controllers as part of it’s
distributed architecture. The enhanced modules offer
an improved processor and increased memory, plus
feature an embedded crypto memory chip that
provides a secured layer of encryption to onboard
sensitive data.
The ICMMR-52 panel comprises of an Authentic Mercury MR Series Intelligent reader interface MR-52 along with optional accessories, i.e., UL certified power supply, charging circuit, battery and a tamper switch.
The ICMMR-52 supports two doors and four card readers, eight general-purpose input monitor points and six control relays for access control and security monitoring through IDCUBE’s MLP series Access Control Panels. With two-wire RS-485 connectivity, the panel’s reader port supports OSDP, OSDP Secure Channel, FICAM government profiles, keypads, biometric readers, Wiegand, clock and data, magnetic stripe, F/2F and supervised F/2F reader technologies. The system configuration and setup are provided through IDCUBE’s Access360 and INEST applications
KEY FEATURES
·
2 door - 4 reader interface panel (OSDP) or 2 door - 2
reader
interface panel
(Wiegand); 8 general-purpose input monitor
points and 6 control
relays
·
AES 128/256 bit data encryption for optimal data
protection
HSPD-12/FIPS201 compliant
UL 294 recognized, CE
compliant, FCC, RoHS
·
Degradation mode to locally process access request
based on
facility code
verification, even when disconnected from an
intelligent controller;
up to 8 facility codes may be active in
each ICMMR-52
·
Supports OSDP, OSDP Secure Channel, FICAM government
profiles, keypads,
biometric readers, Wiegand, clock and
data, biometric template
transfer, magnetic stripe, F/2F and
supervised F/2F reader
technologies
·
RS-485 host connectivity
I/Os support assignment
to door related functions or to
general purpose I/O. The
inputs support normally open,
normally closed,
supervised & non-supervised circuits.
Output relays are
configurable for fail-safe or fail secure
operation
·
12 or 24 V DC input power support